| Specifications |
| Input Voltage: |
115/230 VAC +- 10%, 60/50 Hz, Single Phase
|
| Output Voltage: |
0-90 or 0-180 VDC
|
| Form Factor (AC amps/DC amps): |
1.37
|
| Field Supply Voltage: |
50/100/200
|
| |
• Speed range and regulation: 1% regulation over 50:1 speed range. 1% regulation over 60:1 speed range with the addition of a tachometer for feedback.
|
| |
• 4 Quadrant reversing: Regenerative / 4 quadrant drives have the ability to perform quick, contactorless, reversing on-the-fly.
|
| |
• Stopping modes: User can decelerate (N.O.), regeneratively brake (N.O.) or coast the motor to a stop (N.O.). User can also decelerate t minimum speed (N.O.).
|
| |
• Cage Clamp terminal block: Quick and easy wire terminations.
|
| |
• User Adjustable calibration pots: IR compensation, forward torque, reverse torque, tachometer, min speed, max speed, forward acceleration, reverse acceleration, and deadband.
|
| |
• Additional Features: Dual voltage AC input, switch selectable armature or tachometer feedback mode and field supply for shunt wound motors.
|
| |
• Ob board fusing: No need to add external fusing for protection of your motor or drive.
|
| *: |
Heatsink part-number 170-990-0200 required above 7 amp DC.
|